Infrastructure:APC RackPDU: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
We have a total of 15 APC Power Distribution Units. These allow for remote power monitoring and cycling for all connected devices. | We have a total of 15 APC Power Distribution Units. These allow for remote power monitoring and cycling for all connected devices. | ||
===Specifications=== | |||
[http://www.apc.com/resource/include/techspec_index.cfm?base_sku=AP7900 AP7900] | |||
[??? MasterSwitch VM] | |||
===Details=== | |||
* Nebula units reachable from cluster head only. | |||
* Research units reachable from dreadnought and navajo only | |||
** IP range 192.168.254.NNN where NNN is the unit number. | |||
** Access details same as [[Infrastucture:GigSwitchStack|GigSwitchStack]] | |||
===Device List=== | |||
* The following units are connected to Nebula, and are all MasterSwitch VM units. | * The following units are connected to Nebula, and are all MasterSwitch VM units. | ||
** APC01 - node001 to node022, 2 unlabeled outlets | ** APC01 - node001 to node022, 2 unlabeled outlets | ||
Line 18: | Line 30: | ||
** APC14 - offline, intended for switch stack | ** APC14 - offline, intended for switch stack | ||
** APC15 - for beige boxes, located on shelving | ** APC15 - for beige boxes, located on shelving | ||
Revision as of 00:05, 13 April 2005
We have a total of 15 APC Power Distribution Units. These allow for remote power monitoring and cycling for all connected devices.
Specifications
AP7900 [??? MasterSwitch VM]
Details
- Nebula units reachable from cluster head only.
- Research units reachable from dreadnought and navajo only
- IP range 192.168.254.NNN where NNN is the unit number.
- Access details same as GigSwitchStack
Device List
- The following units are connected to Nebula, and are all MasterSwitch VM units.
- APC01 - node001 to node022, 2 unlabeled outlets
- APC02 - node023 to node044, 2 unlabeled outlets
- APC03 - nodes057,060,063, 21 unlabelled outlets
- APC04 - node064 to node084, 4 unlabeled outlets
- APC05 - node085 to node106, 2 unlabeled outlets
- APC06 - node109,112,115,118,121,124,127 and 17 unlabeled outlets
- The following units are in the Research Server room, and are AP7900 units.
- APC07 - Primary infrastucture rack
- APC08 - Primary infrastucture rack
- APC09 - Central rack
- APC10 - Central rack
- APC11 - Far-left rack
- APC12 - Far-left rack
- APC13 - offline, intended for switch stack
- APC14 - offline, intended for switch stack
- APC15 - for beige boxes, located on shelving